Tripp Lite PDU Metered 16 C13 4 C19 3.2/3.8kW 208/240V C20/L6-20P 10ft Cord

IMG
Tripp Lite PDU Metered 16 C13 4 C19 3.2/3.8kW 208/240V C20/L6-20P 10ft Cord - Metered - NEMA L6-20P, IEC 60320 C20 - 16 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - 0U - Vertical/Toolless - Rack-mountable, Wall-mountable
$244.84Retail $357.56
  • 16 C13 and 4 C19 200-240V outlets distribute AC power to connected equipment
  • Digital ammeter for on-site real-time load monitoring helps prevent power overloads
  • Switchless design helps prevent accidental shutdowns that can lead to costly downtime
  • 10-ft. (3.05 m) detachable cord with L6-20P single-phase input connects to AC power source
  • 40 in. 0U PDU with included mounting brackets installs in rack or under counter
  • 2-year limited warranty
By:
Tripp Lite
Manufacturer:
Tripp Lite by Eaton
Product ID:
108813
Item:
PDUMV20HV-36
UPC Code:
037332255921
Our Part #
8JT722
Condition
New
$244.84EA
$357.56
Availability Only 187 Left In Stock
Great Deals Everyday

You may be also interested

Product description

Tripp Lite PDU Metered 16 C13 4 C19 3.2/3.8kW 208/240V C20/L6-20P 10ft Cord - Metered - NEMA L6-20P, IEC 60320 C20 - 16 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - 0U - Vertical/Toolless - Rack-mountable, Wall-mountable
Metered - NEMA L6-20P, IEC 60320 C20 - 16 x IEC 60320 C13, 4 x IEC 60320 C19 - 230 V AC - 0U - Vertical/Toolless - Rack-mountable, Wall-mountable

Specifications

Mounting Orientation
Vertical/Toolless
PDU Type
Metered
Phase
Single Phase
Power Rating (Watt)
3840 W
Receptacle Detail
16 x IEC 60320 C13
Receptacle Detail
4 x IEC 60320 C19
UPC Alternates
037332255921
Additional Information

ENVIRONMENTAL

  • Storage Temperature Range: -30°C to +50°C (-22°F to +122°F)
  • Relative Humidity: 0-95% non-condensing

USER INTERFACE ALERTS & CONTROLS

  • Front Panel LCD Display: Digital meter reports PDU output current in amps
  • Switches: n/a

Brand Name
Tripp Lite
Certifications & Standards

STANDARDS & COMPLIANCE

Certifications:

  • Tested to UL60950-1 (USA) CAN/CSA (Canada) NOM (Mexico) CE; Series Number (s) AGPD6674; Safety Standards (Canada); CAN/CSA-C22.2 No. 60950-1:2007 (2nd Ed) +A1:2011 +A2:2014; Safety Standards (U.S.) UL60950-1:2007 (2nd Ed)+A1 R10.14; Safety Standards (International) IEC60950-1:2005 (2nd Ed)+A1:2009+A2:2013
Cord Length
10 ft
Country of origin
China
Depth
3.8"
Environmental Certification
RoHS
Environmentally Friendly
Yes
Height
39.8"
Input current
20 A
Input voltage
230 V AC
Limited Warranty
2 Year
Manufacturer
Tripp Lite by Eaton
Manufacturer Part Number
PDUMV20HV-36
Manufacturer Website Address
http://www.tripplite.com
Marketing Information

Single-Phase PDU Distributes and Monitors Network-Grade Power in Real Time

This metered PDU provides real-time local reporting of the total load level via its built-in digital current metering. Ideal for network IT applications small computer rooms and other equipment rack applications the PDUMV20HV-36 features 16 C13 and four C19 200-240V outlets for connecting equipment. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. The switchless design helps prevent an accidental shutdown which could lead to costly downtime.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels even while adding new equipment can keep your TCO (total cost of ownership) low.

Versatile Installation Options Give You Plenty of Choices

The 40-inch 0U PDU mounts vertically in an EIA-standard 19-inch rack using the included toolless mounting buttons or the included mounting brackets with user-supplied hardware. You may also use the brackets to secure the PDU to the underside of a counter with the addition of two user-supplied screws. Bolt-down retention brackets keep power cords organized and your rack free of clutter.

Compatible with a Variety of Input Cords to Fit Your Facility's Power Source

The PDU's C20 inlet accepts a variety of 16A international cordsets. An included 10-ft. (3.05 m) cord with NEMA L6-20P input plug connects to an AC power source generator or protected UPS system to distribute power to connected loads.

Mount Type
Wall-mountable
Mount Type
Rack-mountable
Output voltage
240 V AC
Output voltage
220 V AC
Output voltage
200 V AC
Output voltage
208 V AC
Package Contents
  • PDUMV20HV-36 20-Outlets PDU
  • 20 x Plug-lock Insert Sleeves
  • C19 to L6-20P Input Cord 10-ft. (3.05 m)
  • Rack-mounting Hardware
  • Owner's Manual
Placement
Under-counter
Plug/Connector Type
NEMA L6-20P
Plug/Connector Type
IEC 60320 C20
Product Name
PDUMV20HV-36 20-Outlets PDU
Product Type
PDU
Protection Type
Circuit Protection
Protection Type
Accidental Power Shutdown
Protection Type
Overload Protection
Rack Height
0U
Receptacle Type
IEC 60320 C13
Receptacle Type
IEC 60320 C19
Weight (Approximate)
5.20 lb
Width
2.3"