Tripp Lite PDUMNH32HVAT2 18-Outlets PDU

IMG
Tripp Lite PDUMNH32HVAT2 18-Outlets PDU - Monitored - IEC-309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 2U - Wall-mountable, Rack-mountable - TAA Compliant
$1,032.20Retail $1,424.00
  • Built-in HTML5-based LX Platform interface allows you 24/7 remote access
  • Enables redundant A/B power option for single-corded network devices
  • Digital meter for real-time voltage, amp and load monitoring helps prevent overloads
  • 3 m cords with IEC 309 32A Blue inputs connect to separate power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchase
By:
Tripp Lite
Manufacturer:
Tripp Lite by Eaton
Product ID:
126529
Item:
PDUMNH32HVAT2
UPC Code:
037332261441
Our Part #
01JA44
Condition
New
$1,032.20EA
$1,424.00
Availability Only 66 Left In Stock
Great Deals Everyday

You may be also interested

Product description

Tripp Lite 7.4kW 200-240V Single-Phase ATS/Monitored PDU - 16 C13 & 2 C19 Outlets, Dual IEC 309 32A Blue Inputs, 3 m Cords, 2U, TAA - Monitored - IEC-309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 2U - Wall-mountable, Rack-mountable - TAA Compliant
Monitored - IEC-309 32A BLUE (2P+E) - 16 x IEC 60320 C13, 2 x IEC 60320 C19 - 230 V AC - Network (RJ-45) - 2U - Wall-mountable, Rack-mountable - TAA Compliant

Specifications

Network (RJ-45)
Yes
PDU Type
Monitored
Phase
Single Phase
Plug/Connector Detail
2 x IEC 60309 32A BLUE (2P+E)
Power Rating (Watt)
7400 W
Receptacle Detail
16 x IEC 60320 C13
Receptacle Detail
2 x IEC 60320 C19
UPC Alternates
037332261441
Brand Name
Tripp Lite
Country of origin
Taiwan
Depth
12.5"
Environmental Certification
RoHS
Height
3.5"
Input current
32 A
Input voltage
230 V AC
Limited Warranty
2 Year
Management
  • Web Browser
  • SNMP
  • Telnet
  • SSH
Manufacturer
Tripp Lite by Eaton
Manufacturer Part Number
PDUMNH32HVAT2
Manufacturer Website Address
http://www.tripplite.com
Marketing Information
ATS PDU allows real-time current metering and remote power monitoring to help prevent circuit overloads and ensure proper load balance.

Features Single-Phase 32A 200-240V ATS PDU Distributes and Monitors Network-Grade Power in Real Time

This monitored PDU provides real-time remote monitoring of voltage frequency and load levels via its built-in network interface. Ideal for network IT applications small computer rooms and other equipment rack applications the PDUMNH32HVAT2 features 16 C13 and 2 C19 outlets in two load banks each bank protected by a 20A circuit breaker. Dual three-meter power cords with IEC 309 32A Blue inputs connect to separate primary and secondary mains circuits backup generators UPS systems or utility power grids including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds

Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1-5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Built-In LX Platform Network Management Card Allows Remote Access 24/7

The Java-free HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser SNMP telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite's PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations including firmware update checks and backup and restoration of device configurations.

Digital Load Meter Helps Prevent Potentially Expensive Overloads

A digital ammeter reports the total load for all connected equipment in amps and kilowatts. Monitoring capacity helps ensure load levels remain well below maximum capacity levels with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels even while adding new equipment can keep your TCO (total cost of ownership) low. Current monitoring provides 1% billing grade accuracy

Mounts into 2U of Rack Space or on a Wall

Use the included mounting hardware to install the all-metal housing into 1U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter.

TAA-Compliant for GSA Schedule Purchases

The PDUMNH32HVAT2 is compliant with the Federal Trade Agreements Act (TAA) which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.
Mount Type
Wall-mountable
Mount Type
Rack-mountable
Output voltage
200 V AC
Output voltage
220 V AC
Package Contents
  • PDUMNH32HVAT2 18-Outlets PDU
  • Configuration Cable USB-A to USB Micro-B
  • Rack-Mounting Hardware
  • Installable plug-Retention Sleeves
  • Cable Ties
  • Owner's Manual
Plug/Connector Type
IEC-309 32A BLUE (2P+E)
Product Name
PDUMNH32HVAT2 18-Outlets PDU
Product Type
PDU
Protection Type
Overload Protection
Rack Height
2U
Receptacle Type
IEC 60320 C13
Receptacle Type
IEC 60320 C19
Weight (Approximate)
13.70 lb
Width
17.5"

Product ratings & Reviews

0.0
Based on 0 reviews
5
4
3
2
1

Recently Viewed Products