By clicking Subscribe, I agree to receive advertising and other marketing messages from Patzon under the terms of the Privacy Policy and User Agreement. |
$1,216.32 | Retail $1,844.20 |
Tripp Lite UPS Smart 1000VA 900W 120V LCD USB DB9 Ext Run WEBCARDLX 2URM - 2U Rack/Tower - AVR - 4.50 Hour Recharge - 6.30 Minute Stand-by - 120 V AC Input - 110 V AC, 115 V AC, 120 V AC Output - 8 x NEMA 5-15R
2U Rack/Tower - AVR - 4.50 Hour Recharge - 6.30 Minute Stand-by - 120 V AC Input - 110 V AC, 115 V AC, 120 V AC Output - 8 x NEMA 5-15R
1000VA/900W/120V Battery Backup for PC Networks Security Systems or Digital Signage
The SmartPro® line-interactive SMART1000RMX2UN UPS system with AVR provides reliable battery backup and AC power protection against blackouts brownouts overvoltages surges and line noise that can damage valuable electronics or destroy data. The eight-outlet 120V battery backup with 0.9 power factor is ideal protection for small networks wiring closets security systems telecom high-end PC gaming digital signage equipment and other professional applications including retail casino and hotel/motel management.
Reliable Expandable Battery Backup Keeps You Operational Through Power Outages
Backup support allows you to work through short power failures and gives you enough time to safely save files and shut down your system in case of a prolonged blackout. Backup time varies according to load but the line-interactive UPS system should keep a half load (450W) powered as long as 18 minutes and a full load (900W) up to 6.3 minutes. For mission-critical applications demanding scalable extended runtime the UPS supports external battery packs such as Tripp Lite's BP36V27-2US (sold separately).
WEBCARDLX Network Interface Offers 24/7 Remote Access for Monitoring and Control
The Java-free HTML5-based WEBCARDLX enables full remote access for site power and UPS status monitoring configuration control and email notifications via secure web browser SNMP telnet or SSH. It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Automated alerts help prevent accidental overloads power loss and downtime. WEBCARDLX allows you to use the Auto Probe feature which can prevent costly service calls by automatically rebooting non-responsive network devices.
8 NEMA Outlets Protect Your Connected Components
Eight 5-15R outlets provide battery backup 570 joules of surge protection and voltage regulation for your crucial components. Two independently switched two-outlet load banks enable both scheduled and real-time remote rebooting and load shedding.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage data loss and performance problems caused by brownouts and overvoltages. The SMART1000RMX2UN can correct brownouts as low as 83V and overvoltages as high as 147V back to nominal 120V power continuously all while keeping the battery fully charged and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
Designed for High Efficiency to Help You Save Money and Protect the Environment
A 95% efficiency rating reduces BTU emissions energy consumption and ultimately your energy costs.
Silenceable Alarm and Easy-to-Read LCD Keep You Informed Around the Clock
The front-panel LCD lets you monitor important data such as load level power factor voltage battery charge and estimated runtimes. It rotates for comfortable viewing in both rack and tower configurations. The audible alarm sounds for power failure low battery and overloads. You may silence it using the built-in switch or disable it.
Reliable Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP48VRM2U sold separately).
Pre-Installed LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface enables full remote configuration and management including load shedding reboots of connected equipment and safe shutdowns. The IP-based Auto Probe feature ensures continuous network uptime by communicating with other network devices detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT E2MTDO and E2MTHDI all sold separately) provide a variety of environmental monitoring and control options.
NEMA 5-15R Outlets Protect Your Connected Components
Eight managed 5-15R outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four outlets are grouped into two programmable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage data loss and performance problems caused by brownouts. The SMART1000RMX2UN maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer.
Front Panel LCD Information And Configuration Screen: